Security Systems
Grasbrunn
05-February-2015
Page 7 of 38
Miscellaneous
If the number of entries in the Alarm List becomes too large (>1000),
Operator Client runs possibly very slow.
Permissions for sequences are ignored for sequences placed on maps
The user can access a sequence for which the permission was removed. This happens when the
sequence has been saved as Favorite earlier.
If you configure both a local and an Enterprise user group each with LDAP, only the local LDAP
user group can be used. The Enterprise user LDAP configuration is always ignored.
Bosch VMS pre-alarm default is set to be 10 seconds. When a user updates from a previous
version to 5.5., the system behavior might change due to the fact that depending on the camera
capabilities, the pre-alarm recording might now record in the RAM after update (thus not shown
in Timeline any more).